Name
of the equipment:
Eddy
Current Flaw Detector
Make
& Model:
Olympus
Corporation, Tokyo- Japan
NORTEC600
I-Stem
Registration ID-
3224878
Category
of Instrument
Non-destructive
Testing (NDT) Instrument
Types
of Analysis / Testing
Electromagnetic/Eddy
Current Testing
Application:
Used to detect surface and near-surface
flaws in conductive materials
Description
of Instrument
An
eddy current flaw detector uses electromagnetic induction to identify
cracks, corrosion, and other defects in conductive materials without
damaging the test object.
|


Eddy Current Flaw
Detector
|
Display
|
Display size (W × H, diagonal)
|
117.4 mm × 88.7 mm, 146.3 mm
|
Display type
|
Full VGA (640 × 480 pixels) color,
transflective LCD (liquid crystal display).
|
Screen modes
|
Normal or Full screen, 8 color
schemes.
|
Grids and display tools
|
Choice of 5 grids; crosshairs
(single trace displays only).
|
Connectivity and memory
|
PC software
|
NORTEC PC software, included in
base NORTEC 600 kit. NORTEC PC allows viewing saved files and printing
reports.
|
Data storage
|
500 traces of 120 s max featuring
user-selectable on-board preview.
|
Interface
|
Languages
|
English, Spanish, French, German,
Italian, Japanese, Chinese, Russian, Portuguese, Polish, Dutch, Czech,
Hungarian, Swedish, and Norwegian.
|
Applications
|
Application Selection menu for easy
and rapid configuration. Automatic lift-off key.
|
Real-Time Readings
|
Choice of up to 2 real-time
readings measuring signal characteristics (selection of 5 amplitude
measurements and 1 angle measurement).
|
Probe types
|
Absolute and differential in either
bridge or reflection configuration. The instrument is fully compatible with
NORTEC Powerlink probes, as well as other main probe and accessory
suppliers.
|
Probe connectors
|
16-pin LEMO and BNC featuring
internal automatic balancing for BNC connector (absolute probes).
|
Frequency range
|
10 Hz to 12 MHz
|
Gain
|
0 dB to 100 dB in 0.1 or 1 dB increments.
|
Rotation
|
0° to 359.9° in 0.1° or 1°
increments.
|
Sweep
|
Variable from 0.005 s to 10 s per
division
(total of 13.3 divisions with FINE grid).
|
Filters
|
Low-pass: 10 Hz to 2000 Hz and wide
band. High-pass: off or 5 Hz to 1000 Hz, user-selectable in constant
“figure 6” or “figure 8” filter type. Continuous null (low-frequency HP
filter): 0.2 Hz, 0.5 Hz, 1.0 Hz.
|
Probe drive
|
LOW, MEDIUM, and HIGH (2 V, 5 V, 8
V).
|
Display erase, persistence
|
Display erase (0.1 s to 60 s),
persistence (0.1 s to 10 s)
|
Available alarm types
|
3 simultaneous alarms. Choices
include BOX (rectangle), POLAR (circle), SECTOR (pie), SWEEP (time-based),
CONDUCTIVITY, and COATING THICKNESS.
|
Conductivity (NORTEC
600C, NORTEC 600S, and NORTEC 600D)
|
Frequency
|
60 kHz or 480 kHz
|
Digital conductivity specification
|
Digital conductivity display from
0.9% to 110% IACS or 0.5 to 64 MS/m. Accuracy within ±0.5% IACS from 0.9%
to 65% IACS and within ±1.0% of values over 62%. Meets or exceeds BAC 5651
specifications.
|
Non-conductive coating thickness
|
Can measure non-conductive coating
thickness from 0 mm to 0.648 mm. Accuracy of 0.025 mm
(±0.001 in.) over a 0 mm to 0.64 mm range.
|
Scanners (NORTEC 600S
and NORTEC 600D)
|
Scanner compatibility
|
Operates Olympus scanners
(MiniMite, SpitFire, RA-2000, and PS-5) and other major supplier scanners,
from 120 RPM to 3000 RPM.
|
Dual Frequency (NORTEC 600D)
|
Frequency adjustment (dual
frequency mode)
|
Two fully independent frequencies,
operating in simultaneous injection.
|
MIX options
|
F1 - F2, F1 + F2, and automatic
true mixing.
|
·
Type of
Samples to be Analysed
·
Maximum No.
of Samples Accepted at a Time- 1
·
Minimum No of
Days Required for Analysis – 2 Days
|

Internal
|
External Academic Institutes
|
National R&D Lab
|
Industry
|
200/- per hour
|
400/- per hour + GST
|
400/- per hour + GST
|
400/- per hour + GST
|
|