Thermo Gravimetric Analyzer (TGA)

Name of the equipment:

Thermo gravimetric Analyzer ( TGA)

 

Make & Model:

TA Instruments, TGA Q50

 

I-Stem Registration ID:

3245421

 

Category of Instrument

Thermal Analysis

 

Types of Analysis / Testing

Characterisation & Testing

 

Application:

Thermal stability of the material, Decomposition of multi component system, Estimated life time of the material, Moisture & volatile contents of materials.

 

Description of Instrument

TGA measures the amount & rate of change in the weight of a material as a function of temperature or time in a controlled atmosphere.

Booking Details 

 

 

 


Book through I-STEM:

https://www.istem.gov.in/

 

Slot Booking Link

I-STEM Slot Booking link for External User

 

Booking available for

Internal and External Both

 

Requisition form for

Internals

Contact DetailsExternals

 

 

 

Faculty In-charge:

Dr. A Sujith

 

Email ID:

 sujith@nitc.ac.in

 

Phone number:

9846475675

 

Technical Staff:

Ruther Tyson Lewis

 

Email ID:

ruthertl@nitc.ac.in

 

Phone number:

9845965130

 

Department

Chemistry

 

Office Email ID: chyoffice@nitc.ac.in

 

Location

Sophisticated Instruments Lab,Dept. of Chemistry

 

Features, Working Principle and Specifications

 


Features of the equipment


·         Vertical thermo balance based on null-balance principle.

·         Dual thermocouple design for precise temperature measurements.

 

 

 

Unique features/Measurement capabilities, if any

 

Instrument Technical Description and Major Specifications (This Specifications Limited to Major 5)

 

·         Temperature Range: Ambient to 750 ⁰C

·         Isothermal Temperature Accuracy: ±1 ⁰C

·         Isothermal Temperature Precision: ±0.1 ⁰C

Type of Sample Required for Analysis / Testing (Quantity, Pre-Preparation, State etc.) Guidelines for Sample Submission – User Instructions

Measurement/Sample specifications:

 

 

 

 

 

 

 

 

 

 

 

·         Quantity: 5-10 mg

·         Sample Type: Solid & Liquid.

·         User has to make sure that the solid sample is finely powdered. In-case the solid sample is in other form, the dimensions have to be less than 3mm×3mm×1mm.

·         The User should reveal the toxicity/ hazardous nature of the sample in the requisition form.

·         Minimum No. of Days Required for Analysis: 1 week

 

User Charges Rs. (GST Extra) 

 

                 

Solid/Liquid samples (RT - 750 ᴼC)

NIT Calicut User

(a) Rs. 200/- (for 10 ᴼC/min);

(b) Rs. 50/- (extra for <10 ᴼC/min)

External Academia Research institute User

(a) Rs. 500/- (for 10 ᴼC/min);

(b) Rs. 100/- (extra for <10 ᴼC/min)

National lab User

(a) Rs. 750/- (for 10 ᴼC/min);

(b) Rs. 100/- (extra for <10 ᴼC/min)

Industry User

(a) Rs. 1000/- (for 10 ᴼC/min);

(b) Rs. 100/- (extra for <10 ᴼC/min)