Gas Chromatograph System (GC)

Name of the equipment:

Gas Chromatograph System (GC_1)

 

Make & Model:

Thermo Fisher Scientific & Trace 1610 GC

 

I-Stem Registration ID-                               

3245527

 

Category of Instrument

Characterization and Testing.

 

Types of Analysis / Testing

Characterization and Testing (Liquid samples)

 

Application:

It is primarily used to separate and analyze volatile compounds in a gaseous state.

 

Description of Instrument

It is widely used for analysing mixtures in various fields like environmental monitoring, food analysis, clinical analysis, Research in various scientific disciplines.

Booking Details

Contact Details

Book through I-STEM:

https://www.istem.gov.in/

 

Slot Booking Link

I-STEM Slot Booking link for External User

Booking available for

Internal and External Both

 

Requisition form for

Internals

Externals

 

 

Faculty In-charge:

Dr. Raju Dey

 

Email ID:

rajudey@nitc.ac.in

 

Phone number:

 +91-7558035591

Technical Staff:

 Vinay Kumar

              

Email:

vinaykumar@nitc.ac.in 

           

Contact Number:

+91-9131541081

Features, Working Principle and Specifications

Department

Chemistry

 

Office Email ID

chyoffice@nitc.ac.in

 

Location

PG Instrumentation Lab

 

Lab Phone No

……………………………….

 

 

 

 

 

Features of the equipment

 

Gas Chromatograph system with PTV Injector module, GSV-Injector module, FID module, TCD module and Auto Sampler

Unique features/Measurement capabilities, if any

Ψ  Modular design with iConnect injectors and detectors.

Flexible configuration and easy swapping of components.

Instrument Technical Description and Major Specifications (This Specifications Limited to Major 5)

 

§  Advanced electronic gas control (EGC).

§  High performance oven.

§  Intuitive touch screen interface.

§  Enhanced sample handling with AI/AS 1610 autosampler compatibility.

  • Sample Compatibility: Petrochemicals analysis, Environmental monitoring, food and flavour characterization, forensic science.

 

Measurement/Sample specifications:

GC can be used to analyze samples that contain large amounts of organic volatiles, such as blood, saliva, and human breath.

Type of Sample Required for Analysis / Testing (Quantity, Pre-Preparation, State etc.) Guidelines for Sample Submission – User Instructions

 

 

 

 

 

·         Quantity: For liquid– 2 mL vials.

·         Sample Type: Liquid and Gas.

·         Pre-preparation: Ensure proper sample preparation to avoid contamination and ensure accurate results.

·         Type of Samples to be Analyzed – Liquid.

·         Maximum No. of Samples Accepted at a Time- 15/Day

·         Minimum No of Days Required for Analysis – 1 week

User Charges Rs. (GST Extra) 

 

Internal

External Academic Institutes

National R&D Lab

Industry

75/- per sample

200/- per sample

200/- per sample

500/- per sample