Name
of the equipment:
Gas
Chromatograph and Mass Spectrometer
Make
& Model:
GC:
Perkin Elmer Clarus 580
MS: Perkin Elmer Clarus SQ 8 S
I-Stem
Registration ID-
3222319
Category
of Instrument
Analytical
Chemistry
Types
of Analysis / Testing
●
Separation,
identification, and quantification of volatile and semi-volatile compounds;
●
High-sensitivity
mass spectrometric detection;
● Qualitative and quantitative
analysis of complex mixtures
Application:
●
Pharmaceutical
analysis
●
Environmental
testing (viz. VOC analysis)
●
Forensics
& toxicology
●
Food
& flavour analysis
●
Petrochemical
& industrial chemistry
Description
of Instrument
A
high-performance GC-MS system combining the Clarus 580 GC (precise
separation with advanced temperature control) and the Clarus SQ 8S MS
(single quadrupole MS for reliable compound identification).
|

|
|
 |
|
|
 |
Features
of the equipment
✔ Dual-detection
capability (GC with FID/MS for flexible analysis)
✔ Advanced electronic
pressure control (EPC) for precise flow regulation
✔ Universal MS
compatibility with multiple ionization modes (EI)
|
Unique features/Measurement
capabilities, if any
⮚
Mass
Range (MS): 1.2 – 1100 amu
⮚
Scan
Speed (MS): Up to 10,000 amu/sec
⮚
Detection
Limit (GC-MS): Sub-ppb level sensitivity
⮚ Integrated
TurboMass/Simplicity software for automated method setup & data
analysis
|
Instrument
Technical Description and Major Specifications
(This
Specifications Limited to Major 5)
▪
GC
Column Oven Temp Range: Ambient +4°C to 450°C
▪
MS
Ion Source Temp: Up to 350°C
▪
Pressure
Range (GC): 0 – 150 psi
▪
Mass
Spectrometer Resolution: Unit resolution (1 amu)
▪
Data
Acquisition Speed: Up to 20 spectra/second
|
Measurement/Sample
specifications:
▪
Sample
Type: Volatile & semi-volatile organic compounds
▪
Injection
Volume (GC): 0.1 – 2 µL (liquid), 1 – 1000 mL (gas)
▪
Mass
Spec Compatibility: EI (Electron Ionization) only
▪
Column
Compatibility: Capillary columns (0.1 – 0.53 mm ID)
▪
Carrier
Gas: Helium, Hydrogen, or Nitrogen
|
|
|
 |
●
Quantity:
o Liquid: 1 – 2 mL (for
dilution if needed)
o Gas: 50 – 100 mL (in
sealed vials)
●
Pre-Preparation:
o Must be filtered (0.45
µm) to remove particulates
o Should be in volatile
solvent (e.g., methanol, acetone, hexane)
o No heavy salts or
non-volatile buffers
●
User
Instructions:
o Provide expected
compounds (if known)
o Specify required
sensitivity (ppm/ppb)
●
Type
of Samples Analysed:
o Organic compounds
(drugs, pollutants, flavours, etc.)
o Not suitable for metals,
polymers, or inorganic salts
o Maximum No. of Samples
Accepted at a Time: 10 (batch processing possible)
o Minimum No. of Days
Required for Analysis: 2–5 days (depends on complexity)
●
Maximum
No. of Samples Accepted at a Time: 10 (batch processing possible)
●
Minimum
No. of Days Required for Analysis: 2–5 days (depends on complexity)
Internal
|
External Academic Institutes
|
National R&D Lab
|
Industry
|
1500 per sample
|
3000 per sample
|
3000 per sample
|
6000 per sample
|
|